BDCOMS S8500 Series Switch
Large-Capacity Core 10G Routing Switch
BDCOM S8500 series switch is a new generation large-capacity and hi-performance core routing switch series with L2/L3/L4 wire-speed switching capability.
The backplane capacity is up to 2.4 Tbps, max switching fabric reaches 1.52 Tbps, and forwarding rate is 952 Mpps(max).
BDCOM S8503/8506/8510 has a modular design and bases on multi-processor distributed process system and Crossbar switching structure.
It’s a super powerful core switch.

S8503 S8506 S8510
Application
- Backbone layer and aggregation layer of Carrier IP LAN, campus network, E-government net and large-sized business network
Features
Telecom-level Reliability
- 1:1 redundant backup used in Key modules (like MSU. Power)
- Hitless Protection System (HPS) guarantees the reliability of S8503\8506\8510.
- And VRRP, STP, LACP, etc strength the reliability.
Advanced structure
- Modularized design and distributing mode
- Base on multi-processor distributed process system and Crossbar switching structure.
Powerful value-added business
- L2/L3/L4 wire-speed switching capability
- QoS, MPLS, NAT, broadband control, multicast
- Traffic classification and multicast based on hardware and rate limitation, advanced QoS
Large-capacity and hi-performance
- Congestion-less switching fabric up to 1.52Tpbs, routing forwarding rate up to 952Mpps
- Support 512k L3 routing, 512k L2 MAC and 4096 VLAN, 8k control policy
High port density and wire-speed routing and switching
- Rich interface types. 10GE, GE, FE, etc.
Tight Security
- Support ACL, IPSec, MPLS VPN
- Support different superior queues based on port and restriction of ex- and in- bandwidth
based on flow, URPF, DDOS anti-attack, SSH2.0, 802.1x, VLAN and MAC, port NO., IP bonding.
- Anti-virus system
IPv6
- IPv4 and IPv6, tunnel based on handwork/automatic configuration and 6to4 tunnel
- Basic transition technique form IPv4 to IPv6.
- Static IPv6 routing, and dynamic routing protocols, BGP4/BGP4+, RIPng, OSPFv3
MPLS VPN
- L2 MPLS VPN supports Martini (VPWS) and VPLS
- L3 MPLS VPN, with RFC2547bis, has high compatibility
Network management
- RFC 1213 SNMP, management based on Telnet (CLI command) or SNMP (graphical interfaces)
- Web management realized via Broad Director platform.
Technical Specifications
|
S8503 |
S8506 |
S8510 |
Slot |
1*MSU + 2*Access
Modules |
2*MSU + 4* Access
Modules |
2*MSU + 8* Access
Modules |
Backplane Capacity |
1.2T |
2.4T |
3.2T |
Switch Fabric |
UltraEngige I
96Gbps |
UltraEngige I
96Gbps |
UltraEngige II
96Gbps |
UltraEngige II
192Gbps |
UltraEngige II
192Gbps |
UltraEngige III
384Gbps |
UltraEngige III
384Gbps |
UltraEngige III
384Gbps |
UltraEngige IV
768Gbps |
Forwarding Rate |
238Mpps |
476 Mpps |
952 Mpps |
Max No. of 10000M ports |
16 |
32 |
64 |
Max No. of 1000M ports |
96 |
192 |
384 |
Max No. of 100M ports |
96 |
192 |
384 |
CPU |
RISC CPU(RISC 800MHz) |
Flash |
16MB |
SDRAM |
128MB(up to 1GB) |
MAC Address Table Size |
512K |
512K |
512K |
VLAN table Size |
4K |
4K |
4K |
IP Routing TableSize |
512K |
512K |
512K |
Spanning Tree |
802.1D(STP), 802.1w(RSTP), 802.1s(MSTP) |
Routing Protocol |
RIPv1/2, OSPF, BGP |
MPLS |
MPLS, MPLS VPN, MPLS TE |
IPv6 |
Support |
Multicast Protocol |
IGMP, DVMRP, PIM-SM, PIM-DM
|
QoS |
8 dispatching queues per port, support 802.1p, ToS, application
port control, DifferServ, WRR, SP, SWRR, etc. |
ACL |
Standard and Extended ACL, support based IP, source/destination
IP, L3 IP protocol no., TCP/UDP port, IP priority, ToS, time
ranger ACL |
MAC Control |
Support port/MAC binding, MAC ACL |
VLAN |
Port-based VLAN, 802.1Q, support GVRP, PVLAN, Super
VLAN Stacking(QinQ) |
Flow Control |
HOL blocking prevention, Half-duplex: Back Pressure,
Full-duplex: IEEE 802.3x |
ARP |
Support |
DHCP |
Support Client, Relay, Server |
Port Aggregation |
Support 802.3ad, loading balance |
Customer Access |
Support 802.1x |
AAA |
Support RADIUS |
Port Mirroring |
Support |
Broadcast Control |
Support |
Security |
Support MSU redundancy, hot swapped, HSRP, VRRP |
IEEE Standard |
IEEE 802.1D IEEE 802.3 IEEE 802.3u IEEE802.3ad IEEE
802.3x IEEE 802.3z IEEE802.1Q IEEE 802.1P IEEE 802.1w
IEEE 802.1x |
Console Interface |
CLI, WEB |
Console Port |
RS-232 |
Telnet |
Support |
SNMP |
v1, v2, v3 |
SysLog |
Support |
RMON |
1, 2, 3, 9 |
MIB |
Support |
Humidity |
10% ~90% ( no condensing) |
Temperature |
0°C~40°C |
Power Supply |
AC:200-240VAC, 50/60 Hz
DC:-48V |
Power Redundancy |
1+1 redundancy, support hot swapped |
Dimensions(mm) (L×W×H) |
436×450×380mm |
436×450×680mm |
436×450×797mm |
Power Consumption |
700W |
1000W |
1000W |
Support Protocols
Standard
Protocols |
802.3,10BaseT, 802.3u 100BaseTX, 100BaseFX, 802.3z 1000BaseSX, 802.3z 1000BaseLX, 802.3ab 1000BaseT, 802.3ae 10 Gigabit Ethernet, 802.3x Flow Control, 802.3ad Link Aggregation, 802.1p/q VLAN Tagging, 802.1d Bridging, 802.1w Rapid STP, 802.1x User authentication, 802.3 Ethernet Like MIB, Ethernet Interface MIB, SNMP v1, v2c and V3, SNMP MIB II |
OSPF |
RFC 2178 OSPF, RFC 1583 OSPF v2, RFC 1587 OSPF NSSA, RFC 1745 OSPF Interactions, RFC 1765 OSPF Database Overflow,RFC 1680 OSPF Traps,RFC 2154 OSPF w/Digital Signatures (Password, MD-5),RFC2328 OSPF v2,RFC 1680 OSPF v2 MIB,RFC 1997 Communities Attributes,RFC 2368 TCP MD5,RFC 2370 OSPF Opaque LSA Option |
RIP |
RFC 1058 RIP v1, RFC 1723 RIP v2, RFC 1812 RIP Requirements |
IP Multicast |
RFC 1122 DVMRP Host Requirements, RFC 1256 ICMP Router Discovery Protocol, RFC 1112 IGMP,RFC 2236 IGMP v2,RFC 2362 PIM-SM,DVMRP v3-07,RFC 2336 IGMP v2 |
Routing
Protocols |
RFC 791 IP,RFC 792 ICMP,RFC 793 TCP,RFC 783 TFTP,RFC 826 ARP,RFC 768 UDP,RFC 894 IP over Ethernet,RFC 903 RARP,RFC 1027 Proxy ARP,RFC 684 TELNET,RFC 1591 DNS (client),RFC 1812 General Routing,RFC 1541 and 1542 DHCP,RFC 2131 BootP/DHCP Helper,RFC 2338 VRRP |
Other
Protocols |
RFC1354 IP Forwarding MIB,RFC 1757 RMON Groups 1,2,3,9,RFC 2068
HTTP,RFC 2030 SNTP,RFC 2138 RADIUS |
Order Information
BDCOM S8510 |
|
LS8510-Chassis |
BDCOM S8510 core routing switch chassis (10 slots, including 2 MSU
slots and 8 network module slots, dual AC/DC power supply) |
LS85-PWR-AC-1000 |
220V AC power supply for S8510 |
LS 85-PWR-DC |
-48V DC power supply |
|
|
BDCOM S8506 |
|
LS8506-Chassis |
BDCOM S8506 core routing switch chassis (6 slots, including 2 MSU slots
and 4 network module slots, dual AC/DC power supply) |
LS85-PWR-AC-600 |
220V AC power supply for S8506 |
LS85-PWR-DC |
-48V DC power supply |
|
|
BDCOM S8503 |
|
LS8503-Chassis |
BDCOM S6803 core routing switch chassis (3 slots, including 1 MSU slot
and 2 network module slots, dual AC/DC power supply) |
LS85-PWR-AC-600 |
220V AC power supply for S8503 |
LS85-PWR-DC |
-48V DC power supply |
|
|
S8500 modules |
|
MSU |
|
LS85-MSU-I |
Main Switching Unit —UltraEngine I |
LS85-MSU-II |
Main Switching Unit —UltraEngine II |
LS85-MSU-III |
Main Switching Unit —UltraEngine III |
LS85-MSU-IV |
Main Switching Unit —UltraEngine IV |
|
|
Business modules |
|
LS85-48FE-TX |
48-port 10/100M RJ-45 Module |
LS85-24FESFP-4GE |
24-port 100M FX SFP + 4-port 1000M SFP/TX Module |
LS85-32FE-4GE |
32-port 10/100M RJ-45 + 4-port 1000M SFP/TX Module |
LS85-12GE-Combo |
12-port 1000M SFP/TX Module |
LS85-24GE-SFP |
24-port 1000M FX SFP Module |
LS85-24GE-TX |
24-port 10/100/1000M RJ-45 Module |
LS85-48GE-TX |
48-port 10/100/1000M RJ-45 Module |
LS85-1TE-XFP |
1-port 10 Gigabit XFP Module |
LS85-2TE-XFP |
2-port 10 Gigabit XFP Module |
LS85-4TE-XFP |
4-port 10 Gigabit XFP Module |
LS85-8TE-XFP |
8-port 10 Gigabit XFP Module |
|
|
Optical modules |
|
GSFP-TX |
1000M SFP module, 1000BaseT, RJ45 |
GSFP-SX |
1000M SFP module, Multi-mode, 680nm, 500m, LC interface |
GSFP-LX-10 |
1000M SFP module, Single-mode, 1310nm, 10km, LC interface |
GSFP-LX-40 |
1000M SFP module, Single-mode, 1310nm, 40km, LC interface |
GSFP-ZX-80 |
1000M SFP module, Single-mode,1550nm, 80km, LC interface |
XFP-SX |
10 Gigabit XFP Multi-mode, 850nm,300m, LC interface |
XFP-LX-10 |
10 Gigabit XFP Single-mode, 1310nm,10km, LC interface |
XFP-LX-40 |
10 Gigabit XFP Single-mode, 1550nm,40km, LC interface |
|